Control Modules, Sensors and Electrical Accessories - Components

HYDROTRAINER-200 offers an extensive selection of components to meet all your hydraulic / electrohydraulic learning needs and create your custom compositions.

Power supply 24 V

HY9040-XX*: - Voltaje input: 110V - 240VAC. - Output: 24VDC / 5A. - Short-circuit protection. - Input switch and LED display. - Built-in power cable. - ø4 mm terminals for snap conection cables. - Insulating box with screen printed lid. _*Configurable part number. More information: How To Order or Product configurator._

Set of pushbuttons

HY9042: - 2 pushbuttons with spring return. - 2-position selector. - 4 mm female electrical safety connectors. - Insulating box with screen printed lid.

Electrical inputs one push-button

HY9101: - 1 pushbutton with spring return. - 4 mm female electrical safety connectors. - Insulating box with screen printed lid.

Set of 3 relays

HY9041: - It includes three relays with coil 24V and 4 switchable contacts. - LED activated relay display. - 4 mm female electrical safety connectors. - Insulating box with screen printed lid.

Set of cables with electric connector 4mm.

HY9046: - 5 red cables 1.5 m. - 5 black cables 1 m. - 10 yellow cables 0.5 m. - 5 blue cables 0.25 m

Set of cables with electric connector. 20 units

HY9111: - 10 red cables 1.5 m. - 10 black cables 1 m.

Set of connectors + cable for solenoids

HY9272: - Male connectors 4 mm. - Cable 1.5 m. - Ready to connect in solenoid vale coils. - It includes 3 units (1 black connector and 2 grey connectors). - LED indicators.

Electric end of stroke

HY9231: - Retractable roller driven. - 1 contact NO.1 contact NC. - Transparent body and roller with reversible position. - 4 mm female safety connectors.

Indicator light assembly

HY9043: - Includes 8 indicator lights and a beeper. - It has additional female sockets for power supply distribution. - 4 mm female electrical safety connectors.

Electric meter with pre-selection

HY9033: - Includes counting and countdown inputs. - Power supply: 24 V. - Pre-selected electromechanics. - Manual or electric zero clear. - Switched contact. - ø4 mm female electrical safety connectors.

Set of 2 timed relays

HY9057: - Installed in box made of an insulating material with a system for securing to the support panel and ISO serigraph. - Includes two timed relays: one for connection and the other for disconnection. - With 24 V coil and switch contact. - It has an LED timer state indicator. - Programmable time between 0.1 sec and 1 hour. - 4 mm electrical safety connections.

Benchtop PLC module

PN4143-XX-XX*: Benchtop PLC module. Available for different PLC brands: - Alpha2 AL2-24MR-D (15 inputs and 9 outputs to relay). - Siemens S7-1200 (8 digital inputs, 6 digital outputs to relay and 2 analogue inputs). - Allen Bradley Micro830 (10 digital inputs, 6 digital outputs to relay and 2 analogue inputs). Includes: - All the inputs and outputs are accessible by female quick connection sockets for cables with 4 mm safety terminals. - Simulation of analogue and digital inputs by potentiometers and switches. - 24Vdc power supply. - LED output activation indicator. - Power supply: 100-240Vac - Built-in power cable. - _Programming tools not included. Consult for other PLC brands._ _*Configurable part number. More information: How To Order or Product configurator._

Pressure switch

HY9229: - It emits an electrical signals when the preset pressure value is reached. - Output via switched potential-free contact. - Pressure adjustable between 0 - 40 bar. Max. Pressure: 125bar. *Cable for SAI9271 pressure switch required.

Cable for pressure switch

HY9271: - Ready to connect to pressure switch. - Male connectors ø4 mm. - Cable length: 1.5 m. - LED indicators.

In line pressure filter

HY9287: - Oil filter to fit at the high pressure input of the user circuit. - 10 µ cartridge. B10=75. Max. Pressure: 10 bar. - With electrical clogging indicator. - Includes electrical connector with two LEDs (red, green) and output switched by free voltage contact. - On base plate with three quick-fit male connectors R 1/4”.

Inductive sensor

HY9276: - Adjustable detection distance: 2 mm. - M12, possibility of adjusting the detection distance. - Transistorised output, with indicator LED. - Three socket safety wiring on screen printed plate for correct connection.

Capacitive sensor

HY9277: - Adjustable detection distance: 4 mm. - M12, possibility of adjusting the detection distance. - Transistorised output, with indicator LED. - Three socket safety wiring on screen printed plate for correct connection.

Optical sensor

HY9278: - Adjustable detection distance: 100 mm. - M18, possibility of adjusting the detection distance. - Transistorised output, with indicator LED. - Four socket safety wiring on screen printed plate for correct connection.

Power supply module for two proportional coils

HY9309-XX*: - Electronic unit for entering the electric signals to the proportional valves. Manual control. - Potentiometer for controlling the output intensity to coils a or b. - Dither frequency on/off switch and Dither frequency value adjustment. - I max. = 0.9 A per coil. - 2 ammeters for displaying the current via coils a or b. - Overload electronic internal protection. _*Configurable part number. More information: How To Order or Product configurator._

Set of connectors for proportional coils

HY9303: - Connectors with LED indicators (screen type). Long. 1.5 m. - It includes 2 units (1 grey connector and 1 black connector).

Digital amplifier cards PZD-PWD for proportional coils

HY9310: - Electronic unit for entering the electric signals to the proportional valves. Automatic control. - For the control and regulation of systems with proportional solenoid valves. - Controlled by microprocessor without potentiometers, input, reading and graphic display of parameters by PC. Internal and external set point introduction possibility. - Acceleration / deceleration slopes. - PID digital regulator. - ø4 mm security terminals. - 1 Software license included for PC. 1 communication cable included (PC – card).

Generator of external setpoints

HY9311: - Electronic unit for entering the electric control setpoint to the digital amplifier cards SAI9310. - With multi-turn potentiometer, output current 0 ~ ±10 VDC. - In screen printed insulating box, with connections by means of ø4 mm coloured safety sockets.

Tachometer

HY9312: - For mounting on the motor and obtaining a voltage value in proportion with the rotation speed (speed control). - Output 0 - +/-10 VDC. Bidirectional. - With coupling for piston motor SAI9220. - ø4 mm security terminals.

Analogue position transducer for motor

HY9313: - For mounting on the motor and obtaining a voltage value in proportion to the rotation angle. (Position control). - Output 0 ~ 10 VDC. Bidirectional. - R = 4.7 KΩ. - With coupling for piston motor SAI9220. - ø4 mm security terminals.

Pressure transducer with digital indicator

HY9314: - Converts the pressure value at any point into a proportional electrical signal (V). - Pressure range = 0 ~ 64 bar. - Output 4 ~20 mA. - Built-in pressure switch function.

Product configurator

Do you want to request a quote on this product and get the specifications and technical descriptions of it? Configure your ideal system through our product configurator and get all the related information in just a couple of clicks.