ENS-200 includes the most common consumption sources for an automated process.
We can distinguish the following elements in ENS-200: vacuum area, blowing area, actuator area, HMI (Human Machine Interface) with a built-in PLC, air treatment unit, labels for cables, electric connection terminals, anodised aluminium structure and documentation (user manual, practice manual, theoretical course on pneumatics and energy saving concepts and theoretical exercises based on a consumption calculation tool (included).
• VACUUM AREA ENS-200 includes venturi and multi-stage vacuum ejectors which can be used to check the impact of including high-performing elements in vacuum applications. (Area marked in yellow in the image below).
• BLOWING AREA ENS-200 includes two blower guns, built differently with varying efficiency, plus interchangeable nozzles that can be used to obtain comparative efficiency results. (Area marked in orange in the image below).
• ACTUATOR AREA It includes a standard cylinder and a high-performing cylinder, as well as valves and controllers which can simulate leaks or analyse the impact of an incorrectly dimensioned facility. Actions and strategies can, therefore, be devised from the results obtained. (Area marked in blue in the image below).
|